Description
Absolutely. I’ve extracted the specification from the image and formatted it into a copy-paste-friendly table for your WooCommerce product description.
Technical Specification
| Specification | 30 kW | 60 kW | 120 kW | 240 kW | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Input Power | ||||||||||||
| Input Voltage (AC) | 3 Phase, 350 V AC – 456 V AC | 3 Phase, 350 V AC – 456 V AC | 3 Phase, 350 V AC – 456 V AC | 3 Phase, 350 V AC – 456 V AC | Frequency | 50 Hz – 60 Hz | 50 Hz – 60 Hz | 50 Hz – 60 Hz | 50 Hz – 60 Hz | Wires | 5 Wire AC System (3 Ph, N, PE) | 5 Wire AC System (3 Ph, N, PE) | 5 Wire AC System (3 Ph, N, PE) | 5 Wire AC System (3 Ph, N, PE) | THD |
| < 5% of Nominal Voltage (IEEE 519 Compliant) | < 5% of Nominal Voltage (IEEE 519 Compliant) | < 5% of Nominal Voltage (IEEE 519 Compliant) | ||||||||||
| < 5% of Nominal Voltage (IEEE 519 Compliant) | Power Factor | > 0.98 (Full Load) | > 0.98 (Full Load) | > 0.98 (Full Load) | > 0.98 (Full Load) | Output Power | ||||||
| Number of Outputs | 1 | 1 | 2 | 2 | Output Current | Max. | ||||||
| 250 A | Output Power | Max. | ||||||||||
| 240 kW | Output Connector | CCS2 | CCS2 | CCS2 | CCS2 | DC Output Voltage | 200 V DC – 1000 V DC | 200 V DC – 1000 V DC | 200 V DC – 1000 V DC | 200 V DC – 1000 V DC | Efficiency | > 0.95% | > 0.95% | > 0.95% | > 0.95% | Environment |
| Operating Temperature | -25 °C to 55 °C | -25 °C to 55 °C | -25 °C to 55 °C | -25 °C to 55 °C | Storage Temperature | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | Altitude | Up to 2000 meters | Up to 2000 meters | Up to 2000 meters | Up to 2000 meters | Humidity | 5% to 95%, non-condensing | 5% to 95%, non-condensing | 5% to 95%, non-condensing | 5% to 95%, non-condensing | User Interface & Control |
| 10.1″ TFT LCD Touchscreen (optional 7″) | 10.1″ TFT LCD Touchscreen (optional 7″) | 10.1″ TFT LCD Touchscreen (optional 7″) | ||||||||||
| Languages Supported | English (Customizable to Local Language) | English (Customizable to Local Language) | English (Customizable to Local Language) | English (Customizable to Local Language) | Push Buttons | Red Mushroom Type Emergency Stop | Red Mushroom Type Emergency Stop | Red Mushroom Type Emergency Stop | Red Mushroom Type Emergency Stop | Charge Option | Grid Responsive Metering | Grid Responsive Metering | Grid Responsive Metering | Grid Responsive Metering | Visual Indication | LED Indications (Solid, Blink), HMI | LED Indications (Solid, Blink), HMI | LED Indications (Solid, Blink), HMI | LED Indications (Solid, Blink), HMI | Display Message | As per CCS Specifications | As per CCS Specifications | As per CCS Specifications | As per CCS Specifications | User Authentication | RFID Card (ISO/IEC 14443), Pin, QR code, Mobile application, Autocharge (configurable) | RFID Card (ISO/IEC 14443), Pin, QR code, Mobile application, Autocharge (configurable) | RFID Card (ISO/IEC 14443), Pin, QR code, Mobile application, Autocharge (configurable) | RFID Card (ISO/IEC 14443), Pin, QR code, Mobile application, Autocharge (configurable) | Payment | Smart Card, QR/OTP/APP Server Based Online Payment | Smart Card, QR/OTP/APP Server Based Online Payment | Smart Card, QR/OTP/APP Server Based Online Payment | Smart Card, QR/OTP/APP Server Based Online Payment | Safety |
| Protection | Over Voltage, Under Voltage, Over Current, Surge Protection Device, Reverse Polarity Protection, Over Temperature Protection, Emergency Shutdown, NE (Neutral-Earth) Voltage Tripping, Inbuilt RCMU | Same | Same | Same | EMC | IEC 61000-4 | IEC 61000-4 | IEC 61000-4 | IEC 61000-4 | Compliance | IEC 62196-3, IEC 61851 | IEC 62196-3, IEC 61851 | IEC 62196-3, IEC 61851 | IEC 62196-3, IEC 61851 | Isolation | Double insulation for each DC output (IEC61851-23) | Double insulation for each DC output (IEC61851-23) | Double insulation for each DC output (IEC61851-23) | Double insulation for each DC output (IEC61851-23) | Communication |
| Charger and Vehicle | DIN 70121, ISO-15118 | DIN 70121, ISO-15118 | DIN 70121, ISO-15118 | DIN 70121, ISO-15118 | Charger and CMS | OCPP v 1.6J / 100 Base-T Ethernet (Standard) / Wi-Fi (802.11b/g/n)/GSM Modem (4G/3G/2G) | OCPP v 1.6J / 100 Base-T Ethernet (Standard) / Wi-Fi (802.11b/g/n)/GSM Modem (4G/3G/2G) | OCPP v 1.6J / 100 Base-T Ethernet (Standard) / Wi-Fi (802.11b/g/n)/GSM Modem (4G/3G/2G) | OCPP v 1.6J / 100 Base-T Ethernet (Standard) / Wi-Fi (802.11b/g/n)/GSM Modem (4G/3G/2G) | Mechanical | ||
| Cable Length | 5 meters | 5 meters | 5 meters | 5 meters | IP Rating / Cooling | IP-54 / Forced Natural Air Cooling | IP-54 / Forced Natural Air Cooling | IP-54 / Forced Natural Air Cooling | IP-54 / Forced Natural Air Cooling | Impact | IK10 (screen: IK 08) | IK10 (screen: IK 08) | IK10 (screen: IK 08) | IK10 (screen: IK 08) | Structure | Mild Steel; Flame Retardant Grade UL94V-0 | Mild Steel; Flame Retardant Grade UL94V-0 | Mild Steel; Flame Retardant Grade UL94V-0 | Mild Steel; Flame Retardant Grade UL94V-0 | Mounting | Pedestal | Floor | Floor | Floor | Dimensions (mm) | 700(W) x 600(H) x 240(d) | 750(W) x 1700(H) x 500(d) | 750(W) x 1700(H) x 500(d) | 750(W) x 1700(H) x 750(d) | Weight (Kg) | 86 | 175 | 220 | 270 | Certification |
| Standards | IEC 61851 / AIS 138 Part-2 / IS-17017 | IEC 61851 / AIS 138 Part-2 / IS-17017 | IEC 61851 / AIS 138 Part-2 / IS-17017 | IEC 61851 / AIS 138 Part-2 / IS-17017 | Agency | Part-2 / IS-17017 Certifications ARAI | Part-2 / IS-17017 Certifications ARAI | Part-2 / IS-17017 Certifications ARAI | Part-2 / IS-17017 Certifications ARAI | Management | ||
| Input Supply Failure | 15 minutes for Control System and Billing Unit (Battery Backup) | 15 minutes for Control System and Billing Unit (Battery Backup) | 15 minutes for Control System and Billing Unit (Battery Backup) | 15 minutes for Control System and Billing Unit (Battery Backup) | Power Management | Dynamically Manage the Power Distribution as per Load | Dynamically Manage the Power Distribution as per Load | Dynamically Manage the Power Distribution as per Load | Dynamically Manage the Power Distribution as per Load | Cable | Cable Management System (optional) | Cable Management System (optional) | Cable Management System (optional) | Cable Management System (optional) | Remote Management | Manage via the Admin Portal, and/or API | Manage via the Admin Portal, and/or API | Manage via the Admin Portal, and/or API | Manage via the Admin Portal, and/or API | Service & Maintenance | OTA, Remote monitoring, diagnostic, and proactive maintenance | OTA, Remote monitoring, diagnostic, and proactive maintenance | OTA, Remote monitoring, diagnostic, and proactive maintenance | OTA, Remote monitoring, diagnostic, and proactive maintenance |